Heat Pump Size Calculator

Reviewed by Ameer Hamza, FounderLast reviewed: 17 November 2026Rates last verified: November 2026

What size heat pump do you actually need? Enter your floor area, insulation level and winter design temperature to estimate your home’s peak heat load and the heat pump size that matches it. This is a rule-of-thumb estimate to help you compare quotes — a proper heat-loss survey (Manual J in North America, or an MCS survey in the UK) is what an installer should do before quoting a final size.

Calculate your heat pump size

Choose your country — the outdoor design temperature updates automatically — then adjust the details for your home. Results update live.

Total heated floor area. 150 m² is about 1,615 sq ft.

Your recommended size

11.2 kW (≈ 3.2 tons) heat pump

Peak heat load10.85 kW
Temperature gap31 °C
Heat loss per m²72 W/m²
Peak heat load37,020 BTU/h

How it works

This calculator uses a standard heat-loss rule of thumb. First it works out the temperature gap: gap = indoor temperature − outdoor design temperature. It then scales the insulation heat-loss rate, which is quoted for a 30 °C gap, to your actual gap:

Peak heat load (kW) = floor area (m²) × heat loss rate (W/m²) × (gap ÷ 30) ÷ 1,000

Heat loss per m² = round(heat loss rate × gap ÷ 30). Peak load in BTU/h = peak load (kW) × 3,412. The recommended size is the first standard unit size at or above your peak load, from 3.5, 5, 6, 7.1, 8, 9, 10, 11.2, 12.5, 14, 16, 18, 20 and 25 kW. If your load is above 25 kW, the calculator shows the load rounded up to the nearest 0.5 kW with a “+” to flag that a larger or multi-unit system is likely.

Worked example (USA defaults): 150 m² × 70 W/m² × (31 ÷ 30) ÷ 1,000 = 10.85 kW, so the next standard size up is 11.2 kW.

Heat pump sizing by home size

Quick reference using the US defaults from the calculator above — average insulation (70 W/m²), a 21 °C indoor temperature and a −10 °C design temperature. Your home will differ if your insulation or design temperature differs, so run the calculator with your own details for a figure that matches your home.

Home sizePeak heat loadRecommended unit size
100 m² home7.23 kW8 kW unit
150 m² home10.85 kW11.2 kW unit
200 m² home14.47 kW16 kW unit

Once you know your size, check where backup heat should take over with the Balance Point Calculator, estimate running-cost savings with the Heat Pump Savings Calculator, and compare fuels side by side in the Heating Cost Comparison Calculator.

What this calculator does not include

Use the result as a ballpark to sense-check quotes. If an installer proposes a much larger unit without a room-by-room calculation, ask them to show their working.

Frequently asked questions

What size heat pump do I need for a 150 m² home?

It depends on insulation and how cold your winters get. With average insulation and a 21 °C indoor temperature, a 150 m² home needs about 10.85 kW of heat at a −10 °C design temperature (an 11.2 kW unit), 8.75 kW at −4 °C (a 9 kW unit), and 14.35 kW at −20 °C (a 16 kW unit). Better insulation can cut the required size by a third or more.

Why does insulation change the heat pump size so much?

A heat pump only needs to replace the heat your home loses. A poorly insulated home can lose around 100 W per m² on the coldest day, while a well-insulated new build may lose only 35 W per m². That difference is multiplied by your whole floor area, so insulation — not floor area alone — is often the biggest factor in the size you need.

What is a design temperature and why does it matter?

The design temperature is the cold outdoor temperature your heating system is sized for — close to the coldest conditions your area normally sees in winter. The bigger the gap between that temperature and your indoor temperature, the more heat your home loses and the larger the heat pump you need. This calculator uses −10 °C for the USA, −4 °C for the UK and −20 °C for Canada as typical starting points.

Should I oversize my heat pump to be safe?

Usually not. An oversized heat pump costs more to buy, cycles on and off more often, and can be less efficient and less comfortable than a correctly sized one. Size for your peak heat load at the design temperature, choose a cold-climate model if your design temperature is below about −10 °C, and let a proper heat-loss survey confirm the final choice before you buy.

What size heat pump do I need in tons?

North America often sizes heat pumps in tons: 1 ton = 12,000 BTU/h, which is about 3.517 kW. To convert, divide kW by 3.517 — so the 11.2 kW unit recommended for the default 150 m² home is about 3.2 tons.

Do I need a cold-climate heat pump?

A heat pump's capacity falls as it gets colder outdoors, so a standard unit may deliver far less heat on the coldest day than its nameplate rating. Cold-climate units are designed to hold most of their capacity to −15 °C (5 °F) and below. Always size at your design temperature — the coldest temperature your area normally sees, such as −20 °C in parts of Canada — and check the manufacturer's output at that temperature.

Related calculators

Sources: Sizing method based on standard W/m² heat-loss rules of thumb; design temperatures are typical winter design values for each country.